NWIPB OpenIR
Determination of triterpenic acids in fruits by a novel high performance liquid chromatography method with high sensitivity and specificity
Zhang, Shijuan1,3; Sun, Yuanpeng2; Sun, Zhiwei2; Wang, Xiaoyan1; You, Jinmao1,2; Suo, Yourui1
2014-03-01
发表期刊FOOD CHEMISTRY
ISSN0308-8146
卷号146页码:264-269
文章类型Article
摘要A novel and interesting pre-column derivatisation method was developed for the analysis of triterpenic acids by high-performance liquid chromatography (HPLC) with fluorescence detection. Each triterpenic acid produced two HPLC peaks with similar peak areas after derivatising with chiral 1-(9H-carbazol-9-yl) propan-2-yl-methanesulfonate (CPMS), while the fatty acid derivative of CPMS had only one peak. This phenomenon greatly increased the confidence in analyte confirmation. Compound with only one peak or two peaks differing greatly in their peak areas could be excluded from the target compound list. CPMS was compared with five other derivatising reagents, four of which produced only one peak for one triterpenic acid, to study the possible mechanism. Analytes with different behaviours were also studied to better interpret the mechanism. The proposed method also showed the merits of high sensitivity and less sample consumption. It was successfully applied to the analysis of triterpenic acids in fruit peels and flesh. There is no prior report on the two peak phenomenon of triterpenic acids. The information provided in this study will be helpful for those who are also engaged in derivatisation study. (C) 2013 Elsevier Ltd. All rights reserved.; A novel and interesting pre-column derivatisation method was developed for the analysis of triterpenic acids by high-performance liquid chromatography (HPLC) with fluorescence detection. Each triterpenic acid produced two HPLC peaks with similar peak areas after derivatising with chiral 1-(9H-carbazol-9-yl) propan-2-yl-methanesulfonate (CPMS), while the fatty acid derivative of CPMS had only one peak. This phenomenon greatly increased the confidence in analyte confirmation. Compound with only one peak or two peaks differing greatly in their peak areas could be excluded from the target compound list. CPMS was compared with five other derivatising reagents, four of which produced only one peak for one triterpenic acid, to study the possible mechanism. Analytes with different behaviours were also studied to better interpret the mechanism. The proposed method also showed the merits of high sensitivity and less sample consumption. It was successfully applied to the analysis of triterpenic acids in fruit peels and flesh. There is no prior report on the two peak phenomenon of triterpenic acids. The information provided in this study will be helpful for those who are also engaged in derivatisation study. (C) 2013 Elsevier Ltd. All rights reserved.
关键词Triterpenic Acids Pre-column Derivatisation Hplc Cpms
WOS标题词Science & Technology ; Physical Sciences ; Life Sciences & Biomedicine
关键词[WOS]FREE FATTY-ACIDS ; FLUORESCENCE DETECTION ; URSOLIC ACID ; APPLE PEELS ; IDENTIFICATION ; HPLC ; ANTIOXIDANT ; SEPARATION ; PLANTS ; MS
收录类别SCI
语种英语
WOS研究方向Chemistry ; Food Science & Technology ; Nutrition & Dietetics
WOS类目Chemistry, Applied ; Food Science & Technology ; Nutrition & Dietetics
WOS记录号WOS:000328100200037
引用统计
被引频次:28[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://210.75.249.4/handle/363003/4251
专题中国科学院西北高原生物研究所
作者单位1.Chinese Acad Sci, Northwest Inst Plateau Biol, Key Lab Tibetan Med Res, Xining 810001, Peoples R China
2.Qufu Normal Univ, Shandong Prov Key Lab Life Organ Anal, Qufu, Peoples R China
3.Univ Chinese Acad Sci, Beijing, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Shijuan,Sun, Yuanpeng,Sun, Zhiwei,et al. Determination of triterpenic acids in fruits by a novel high performance liquid chromatography method with high sensitivity and specificity[J]. FOOD CHEMISTRY,2014,146:264-269.
APA Zhang, Shijuan,Sun, Yuanpeng,Sun, Zhiwei,Wang, Xiaoyan,You, Jinmao,&Suo, Yourui.(2014).Determination of triterpenic acids in fruits by a novel high performance liquid chromatography method with high sensitivity and specificity.FOOD CHEMISTRY,146,264-269.
MLA Zhang, Shijuan,et al."Determination of triterpenic acids in fruits by a novel high performance liquid chromatography method with high sensitivity and specificity".FOOD CHEMISTRY 146(2014):264-269.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Determination of tri(932KB) 开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, Shijuan]的文章
[Sun, Yuanpeng]的文章
[Sun, Zhiwei]的文章
百度学术
百度学术中相似的文章
[Zhang, Shijuan]的文章
[Sun, Yuanpeng]的文章
[Sun, Zhiwei]的文章
必应学术
必应学术中相似的文章
[Zhang, Shijuan]的文章
[Sun, Yuanpeng]的文章
[Sun, Zhiwei]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Determination of triterpenic acids in fruits by a novel high performance liquid chromatography method with high sensitivity and specificity.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。